XFP501/X/CON Main panel and the Context Plus XFP 2 Loop 32 Zone model XFP502/X/CON Main panel at remote parts of a site (e.g. all potential fire servi

Ask on WhatsApp
  • Genuine, fully-supported equipment
  • Technical guidance from our engineers
  • Add several products, request one quote
Overview

Product Details

The XFP Networkable repeater panel, 32 zones, code/keyswitch entry, c/w psu and network repeater card, metal enclosure- is part of the Analogue Addressable Fire Detection Panels range from Context Plus, supplied and supported by SPS. XFP501/X/CON Main panel and the Context Plus XFP 2 Loop 32 Zone model XFP502/X/CON Main panel at remote parts of a site (e.g. all potential fire service entrances). Offers all of the functions and controls of an XFP Main panel (access levels 1, 2 and 3). Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply. A maximum of eight XFP510-32/CON Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card (fitted as standard in all XFP510-32/CON repeaters, available as an optional extra on Main XFP 1 loop 32 zone model XFP501/X/CON and the Main XFP 2 Loop 32 Zone model XFP502/X/CON). Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

Specifications & features

  • Protocol/compatibility Compatible with Context Plus XFP 1 loop 32 zone model XFP501/X/CON Main panel and the Context Plus XFP 2 Loop 32 Zone model XFP502/X/CON main panel.
  • Mains supply 230V 50/60Hz.
  • Mains rated current 680mA maximum.
  • Internal power supply 27Vdc nominal.
  • Total output current limited to 3A @ 230Vac (Imax.A 250mA;
  • Quiescent current TBC.
  • Max battery size and type 2 x 12V 7Ah VRLA connected in series.
  • Auxiliary relays Fault (Failsafe;
  • Capable of switching 1A @ 30V DC;
  • Must not be used for switching Mains voltages).
  • PC connection None.
  • Indicators 2 line x 40 character backlit display;
  • 32 Zonal LEDs, General Fire;
  • Remote Output Activated;
  • Remote Output Disabled;
  • Disablement;
  • General Fault;
  • System Fault.
  • Expansion connections On board AFP711 network driver card facilitates the connection of additional XFP Repeaters.
  • Product dimensions (mm) 410 W x 250 H x 80 D mm (base);
  • 439 W x 274 H x 7 D mm (lid).
  • Construction & finish Metal.
  • IP Rating TBC.
  • Weight 4.5kg (no batteries).
  • Operating conditions/temperature -5ºC to +40ºC.